6KV 50HZ Hall Effect Sensor for Switching Mode Power Supplies

5000PCS
MOQ
Negotiation
Price
6KV 50HZ Hall Effect Sensor for Switching Mode Power Supplies
Features Gallery Product Description Chat Now
Features
Specifications
Turns Ratio: 1:2000,1:3000
Rated Input: 100A,200A,300A
Rated Output: 50mA±0.5%, 100mA±0.5%
Linearity: 6KV,50HZ,1min
IP Rating: IP65
Insulation Voltage: Electrical Products/Power
Highlight:

6KV Hall Effect current sensor

,

50HZ switching mode power sensor

,

Hall Effect sensor for power supplies

Basic Infomation
Place of Origin: China
Brand Name: Shinhom
Certification: RoHS
Model Number: HBC-LTA
Payment & Shipping Terms
Packaging Details: Carton
Delivery Time: 4~8 Weeks
Payment Terms: T/T
Supply Ability: 1000000/MONTH
Product Description

The Hall effect current sensor is manufactured using current isolation and Hall effect measurement technology, specifically developed for uninterruptible power supplies and switch-mode power supplies, ensuring high precision, stable performance, and safe isolation. The product features a robust and reliable structure with current isolation between primary and secondary circuits. It is suitable for uninterruptible power supplies, switch-mode power supplies, and welding power supplies. It is an ideal choice for Hall effect current sensor applications in current monitoring and industrial automation.

Features

  • Current isolation between primary and secondary

  • Accurate measurement of DC, AC, and pulse currents

  • Operating current – 0 to 300A

  • Rated output – 50mA ±0.5%

  • Rated output – 100mA ±0.5%

  • Easy to install

  • High accuracy class

  • Customisable nominal input current and output voltage

Applications

  • Uninterruptible power supplies

  • Switch-mode power supplies

  • Welding power supplies

  • Battery-powered applications

  • AC variable frequency drives

  • Servo motor drives

  • DC motor drive static converters

  • Industrial automation

ELECTRICAL DATA:

HBC100LTA HBC200LTA HBC300LTA
Rated input current 100 200 300 A
Test current range 200(±18V,20Ω) 400(±18V,30Ω) 600(±18V,20Ω) A
Turns ratio 1:2000 1:2000 1:3000
Test resistance with±12V @±100Amax 80(max) @±200Amax 80(max) @±300Amax 76(max) Ω
@±200Amax 25(max) @±400Amax 20(max) @±600Amax 22 (max) Ω
with±15V @±100Amax 110(max) @±200Amax 120(max) @±300Amax 100(max) Ω
@±200Amax 40(max) @±400Amax 30(max) @±600Amax 36(max) Ω
Rated output current 50±0.5% 100±0.5% 100±0.5% mA
Supply voltage ±12~±18 V
Consumption current ≤±20 mA
Zero offset current ≤±0.2 mA
Offset current Drift -40℃~85℃,≤±0.5 mA
Response time <1 µs
Linearity ≤±0.2 %FS
Insulation voltage 50HZ,1min,6 KV
di/dt >100 A/μs
Bandwidth(-3dB) DC…100 KHz
Sec winding resistance 21 21 32 Ω
Operating Temperature -40~+85 ℃
Storage Temperature -40~+105 ℃
6KV 50HZ Hall Effect Sensor for Switching Mode Power Supplies

Notes: Product specifications can be customized

FAQ

Q: How to apply for samples? What is the lead time?

A: You can submit a sample application through our website or email. Samples are free of charge and will be shipped within 3-5 working days. Mass order lead time is generally 2-8 weeks; custom products will be confirmed separately.

Q: Do you support small trial orders?

A: Yes. Small trial orders (below the standard MOQ) can be negotiated and receive the same quality standards and delivery commitments as mass orders. Please contact our sales team for details.

Q: Why is this product suitable for UPS and SMPS applications?

A: This product accurately measures DC, AC, or pulse currents, making it suitable for current monitoring in uninterruptible power supplies and switch-mode power supplies. Current isolation ensures safe measurement. The output voltage is measured at the output terminals; care must be taken during wiring to avoid incorrect connections that could damage the sensor.

Recommended Products
Get in touch with us
Contact Person : Jack wang
Tel : 13909218465
Fax : 86-029-87851840
Characters Remaining(20/3000)